• E Instruments E9000-OCN-0-12  Transportable Emissions Analyzer

E Instruments E9000-OCN-0-12 - Transportable Emissions Analyzer

  • O2, CO, NO Gas sensors (Note: Upgradeable to 9 gas sensors total)
  • Bluetooth wireless communications
  • CO dilution auto-range for measurements up to 10%

The E Instruments E9000-OCN-0-12 is a standard E9000 configuration with O2, CO, NO Gas sensors (upgradeable to 9 gas sensors total). It is an advanced transportable emissions analyzer that is a complete, portable tool for EPA compliance - level emissions monitoring of boilers, engines and other combustion equipment.

Display Screen & Keypad

The large multi-color graphic display screen includes a zoom function. The capacitive touch sensing keypad guides the operator through the user-friendly menus on the display screen. The measured & calculated parameters on the display screen can be fully customized as the operator requires.

Built-in Printer

The internal printer is included with each E9000 and prints on a special non-fading polymer paper so it can still be easily read even when exposed to water, heat, or light.  As with the display screen, the parameters on the print-out can be customized by each operator.

Heated Sample Hose & Probe Head

The E9000 has an optional heated probe head and a flexible heated sample line. This feature maintains the sample gas at a temperature higher than the dew point to prevent condensation from occurring before the stack gas reaches the internal thermoelectric chiller. The water vapor condenses very rapidly at the chiller so the gases do not have ample opportunity time to dissolve into the condensate. This sample conditioning system maintains the integrity of the gas composition especially for the most water-soluble gases such as NO₂ and SO₂.

Superior Sample Conditioning for Semi-Continuous Use

Each E9000 includes an internal high efficiency Peltier thermoelectric chiller with a built-in condensate drain pump that automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Along with the optional heated sample hose & probe head, this sample conditioning system allows for longer test periods while maximizing the integrity and composition of the sampled stack gas so the gases measured by the analyzer are representative of the actual stack/flue gases.

E9000 Ordering Code

Part #  9000 - Table A - Table B - Table C

Table A - Electrochemical Sensors (Maximum of Six)

  • O - O2 Sensor (0 - 25 %)
  • C - CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 10%
  • N - NO Sensor (0 - 5000 ppm)
  • NL - Low NO Sensor (0 - 100.0 ppm)
  • D - NO2  Sensor (0 - 1000 ppm)
  • DL - Low NO2 Sensor (0 - 100.0 ppm)
  • S - SO2 Sensor (0 - 5000 ppm)
  • SL - Low SO2  Sensor (0 - 100.0 ppm)
  • H - H2S Sensor (0 - 500 ppm)

Table B - NDIR (non-dispersive infrared) Sensors

  • IR - CO2  Sensor (0 - 50 %), CxHy Sensor (0 - 5 %),  High CO Sensor (0 - 15 %)
  • 0 - No NDIR sensors

Table C - Sampling Probes and Hoses

  • 12 - 12" (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
  • 30 - 30" (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
  • 40 - 40" (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for  High Temperature Combustion Applications
  • 60 - 60" (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications
  • 12H - 12" (300mm) Probe, 1470°F (800°C) max, with 10' (3m) Heated   Sample Hose & Probe Head
  • 40H - 40" (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Heated Sample Hose & Probe Head
  • SINT1 - Sintered Filter with Half Shield for Probe Tip

O2 (0-25%), CO (0-8000ppm), and NO/NOx** (0-5000ppm) Gas Sensors, CO Dilution Auto-Range up to 10%, Stack Gas and Ambient Air Temperature Measurements, Draft and Differential Pressure Measurements, Efficiency, Loss, Excess Air, and CO2 Calculations

  • Includes O2, CO, NO Gas sensors (Note: Upgradeable to 9 gas sensors total)
  • Built–in high efficiency thermoelectric chiller with automatic condensate drain
  • Heated Probe Head & Sample Line
  • Software package with USB & Bluetooth interface
  • Bluetooth wireless communications
  • CO dilution auto-range for measurements up to 10%
  • Automatic long–term monitoring & data logging
  • Enhanced internal memory (16,000 Tests)
  • Full color graphic display screen
  • Built-in printer with non-fading paper
  • High temperature probes with sintered filter
  • Stack gas velocity with Pitot tube
  • Temperature & Pressure measurements

In The Box

  • Rechargeable battery pack
  • 10-240VAC/50-60Hz battery charger
  • 12"/300mm probe with 10'/3m dual hose
  • Software package with USB & Bluetooth interface
  • Heavy duty aluminum carrying case
  • Calibration certificate
  • Operations manual

E Instruments E9000-OCN-0-12 Transportable Emissions Analyzer

  • Product Code: E9000-OCN-0-12
  • Availability: Pre-Order
  • Rp.210,000,000


Tags: Transportable Emissions Analyzer